Skip to main content

Computer placement

A computer that joins the domain lands in the domain's Computers container (or the OU set with redircmp), where none of your Group Policy applies. An automation moves it, by its name, into the right OU and adds it to the right groups: SD542… into room HAC-R401, teacher laptops into CB-WiFi-101-Computers. The computer then gets the OU's Group Policy (and what the groups give it, such as Wi-Fi) at its next refresh or restart. Link your GPOs to the OUs once; never per computer.

Placement is built in the Axis automation editor, as a graph:

  1. A new computer waits in AD (the trigger): Vertex sends each computer it finds in the Computers container to the automations.
  2. AD: Place by name: a table of name prefixes, each with its target OU and groups. Vertex moves the computer by the row whose prefix its name starts with.
  3. What follows Placed, No match and Failed is yours: add the computer to more groups, run a script, e-mail the admins.

See Active Directory steps for the editor. The Automation page in Vertex lists these automations (on or off, last run), opens them in Axis, and starts a new one: Place new computers by name opens the editor with this graph already drawn. It needs the right to build automations in Axis.

Placement rules are retired

Until 25 November 2026, Vertex placed computers itself with placement rules on this page. Rules no longer place anything. While old rules are left, the Automation page shows Old placement rules with Move rules to an Axis automation: Axis opens a new automation with a Place by name step holding every enabled rule as a row, and e-mails to the admins on No match and Failed, not yet saved and off. Review it, save it, switch it on, then choose Send all waiting computers again (below). Delete old rules removes them (Tenant admin, with your password).

Before you start​

  1. Update the Axis connector on the domain controller to v1.6.0 or later. Older connectors cannot read the Computers container: the sync runs as before, and nothing is placed.
  2. In Settings → Directory, switch on Computer placement. Rows that add computers to groups also need Groups and membership on (Getting started).
  3. Check that the Managed OUs cover every target OU and every group of your table.
  4. On the domain controller, from an elevated prompt, switch on the same classes in the local guard: rmm-connector vertex guard set --computer on --group on (--group is only needed for rows with groups; it is on in a new guard).
  5. Build the automation in Axis (above), save it and switch it on.

Then run a sync (Read now on the Overview): the sync also reads the computers sitting directly in the Computers container, and they appear under Waiting in the Computers container. Until then the page says The Computers container has not been read from AD yet.

The Place by name table​

Each row of AD: Place by name has:

FieldWhat to enter
Name prefixThe start of the computer names it places: 1 to 15 letters, digits or hyphens. Each prefix may appear once (upper and lower case count as the same). A whole computer name pins one computer.
Target OUWhere the computers go (distinguished name), inside the managed OUs.
Groups (optional)Up to 10 groups to add the computers to, one distinguished name per line, inside the managed OUs and not protected.

A computer is placed by the row with the longest prefix its name starts with, ignoring case; the order of the rows does not matter. With this table, SD5423 goes to HAC-R401, SD5501 to Students, and TL007 to the teachers' laptops OU and the teachers' Wi-Fi group:

Name prefixTarget OUGroups
SD542OU=HAC-R401,OU=HAC,OU=Students,OU=Computers,OU=_CODING,DC=coding,DC=local
SD544OU=HAC-R402,OU=HAC,OU=Students,OU=Computers,OU=_CODING,DC=coding,DC=local
SDOU=Students,OU=Computers,OU=_CODING,DC=coding,DC=local
TLOU=Laptops,OU=Teachers,OU=Computers,OU=_CODING,DC=coding,DC=localCN=CB-WiFi-101-Computers,…
SLOU=Laptops,OU=Students,OU=Computers,OU=_CODING,DC=coding,DC=localCN=CB-WiFi-102-Computers,…

Up to 200 rows. Saving the automation asks Vertex to check every row (the target OU and groups inside the managed OUs, the switches, your rights: placing needs the Tenant admin role in Vertex); one bad row refuses the save and names the row. A computer no row fits follows No match and is not changed. Dry run says which row a computer would take.

The placement is made on behalf of whoever last saved the automation: it shows in Activity under that person, with the automation's name.

Waiting computers​

Waiting in the Computers container lists the computers directly in that container (shown as Container: …), as the last sync saw them, with their Outcome, Error and First seen. The list updates by itself.

OutcomeMeaning
WaitingJust found; the next check sends it to the automations.
PendingIts placement is running.
PlacedAdded to the groups and moved. It leaves the list with the next sync.
FailedThe placement failed; the error code and message say why (Troubleshooting).
No matchSent to the automations, not placed yet. An automation's Place by name step takes it from here.
ProtectedA domain controller or another privileged computer. It is never placed.

Only computers with a valid computer (NetBIOS) name, 1 to 15 letters, digits or hyphens, are listed; others in the container are ignored.

After every successful sync Vertex checks the container, one check at a time per organization (the page shows Checking… meanwhile), and sends each new computer once to the Axis automations that start with A new computer waits in AD, at most 200 per check (the rest at the next one). A computer is therefore placed within one sync interval of joining, once an automation is on.

Send all waiting computers again (Tenant admin) sends every computer waiting with No match to the automations once more: use it after you switched an automation on or fixed its table. Placed and protected computers are left alone. It is in the audit log as directory.placement.announce.

A placement that fails stays Failed with its error code and message (Troubleshooting); the automation follows Failed (e-mail the admins there). Fix the cause (a switch, the managed OUs, a group, the table), then choose Retry on the computer: it waits again and is sent to the automations once more. Retry is offered on Failed and No match computers, needs the Tenant admin role and your password, is in the audit log as directory.placement.retry with your name, and is refused (placement_running) while the placement is running.

A computer that leaves the Computers container (placed, or moved by hand) drops off the list at the next sync; one that comes back is new again.

What is never moved​

Anyone who may join a computer to the domain chooses its name, so the name only picks one of your rows; it decides nothing else. Vertex matches the name it read from AD itself, not the name in the event. But because the name picks the row, someone who may join computers could name one to land in another row's OU and groups. Keep privileged groups and admin OUs out of the table: it is for pupils' and teachers' rooms and laptops, and groups like the Wi-Fi groups above.

The domain controller checks each placement again before it changes anything, and refuses:

  • a computer that is no longer directly in the Computers container (already placed, moved by hand, or in a sub-OU of it): not_in_intake;
  • a computer renamed since the sync so that the prefix no longer fits: name_mismatch;
  • domain controllers and other protected computers, and the account Vertex works with: protected;
  • a target OU or a group outside the managed OUs (out_of_scope), or a protected group (protected).

It checks every group before it changes anything: one bad group means nothing changes. It then adds the computer to the groups (those it is already in are skipped) and moves it last. If adding to a group fails, the computer stays in the Computers container and shows Failed; Retry does the whole placement again.

A placement with groups also needs Groups and membership on in the settings and --group on in the guard; otherwise it fails with writes_disabled or guard_denied. Vertex checks the switches again when the placement runs.

Limits​

  • 200 rows, 10 groups per row.
  • 200 computers sent to the automations per check; 1,000 events per organization per hour reach Axis.
  • Every placement counts one change plus one per group, against Vertex's change limits and the guard's writes per minute.
  • At most 10,000 computers in the Computers container. With more, the page warns, the sync keeps the last list of waiting computers and sends nothing; users, groups and GPOs still sync normally. Move computers out of the container (or place them by hand) to get below the limit.